DL Electric: Single Pole Current Circuit Breaker

$39.99 $0.00

DL DR8L-40 Single Pole (1P+N) 20A 30mA 100mA 300mA 10KA Current Circuit Breaker Electric Leakage protection RCCB RCBO with Tail Feature highlights: DL DR8L-40 Single Pole (1P+N) RCBO offers robust protection against earth fault leakage and over-voltage, with a rated current of 20A and residual current sensitivity options at 30mA,...

sold in last Hour

HURRY! ONLY LEFT IN STOCK

Ask a Question

Amp

Tax included. Shipping calculated at checkout.

Real time Visitor right now

DL DR8L-40 Single Pole (1P+N) 20A 30mA 100mA 300mA 10KA Current Circuit Breaker Electric Leakage protection RCCB RCBO with Tail

Feature highlights: DL DR8L-40 Single Pole (1P+N) RCBO offers robust protection against earth fault leakage and over-voltage, with a rated current of 20A and residual current sensitivity options at 30mA, 100mA, and 300mA. It ensures reliable performance with magnetic tripping characteristics (B, C), complies with AS NZS 61009-1 standar ds, and operates under calibration temperature of 30°C. The fire-resistant plastic parts endure abnormal heating and strong impact, while automatic disconnection during faults provides enhanced safety.

Supplier highlights: This supplier mainly exports to the United States, Malaysia, and Australia, offering full customization services and boasting a 100.0% positive review rate.

Product descriptions from the supplier

Standard

AS/NZS 61009 - 1

Magnetic tripping characteristics B,C   
Residual tripping characteristics AC
Rated current(A) 6,10,16,20,25,32
Rated residual current(mA) 30, 100,300  
Calibration temperature 30°C  
Rated voltage 1P 240V
Frequency  50/60
Maximum service voltage 264
Tripping Duration Instaneous<0.1s
Power supply Line & Load
Selectivity class 3

Residual making and breaking capacity

2000A

Short circuit capacity

10000A

Isolation application (IEC 60947-2)

Yes

Insulation resistance (Mohm) 1,000

Insulation voltage (V)

500

Endurance (operations) electrical >5, 000 
Mechanical > 10,000
Protection degree outside IP20
Self extinguishing degree (UL 94) V2 
Tropicalisation (IEC 60068-2) +55°C/95% RH  
Operating temperature  -5/+55°C  
Storage temperature -25/+70°C 
Terminal capacity (top & bottom) min / max 1-16mm
Terminal torque (top / bottom) 3
Busbar systems Yes
Accessories No
Dimensions (mm) 72(H)107(L)18(W)
Weight (g) 125